Air/Water/Soil Temperature Sensor

£

Air/Water/Soil Temperature Sensor

Overview

The TMC temperature probe can be used in air, soil & water work with the UX120-006M, ZW Series or U Series of data loggers. Temperature probes are available in lengths of 0.3 m (1 ft), 1.8 m (6 ft), 6.1 m, (20 ft) & 15.2 m (50 ft).

Highlighted Features

  • Plug directly into the external input jacks of U12, UX120, or ZW Family loggers to expand the range of measurement options and applications

In what environment does this sensor operate?

This sensor operates in indoor, outdoor and underwater environments.

What measurements does this sensor support?

The TMCx-HD sensor supports the following measurements: Temperature and Water Temperature

The country of origin for this product is the United States. To see the full specifications for this product, please see our product manual found under the documentation tab if available

 

 

 

 

Measurement range: -40° to 50°C (-40° to 122°F) in water; -40° to 100°C (-40° to 212°F) in air
Accuracy:
     w/U12: ±0.25°C from 0° to 50°C (±0.45°F from 32° to 122°F), insert probe 2.3 cm (0.9 inches) minimum; 
     w/ZW: ±0.21°C from 0° to 50°C (±0.38°F from 32° to 122°F), insert probe 2.3 cm (0.9 inches) minimum; 
     w/UX120-006M, MX1104, and MX1105: ±0.15°C from 0° to 70°C (±0.27°F from 32° to 158°F), insert probe 2.3 cm (0.9 inches) minimum; 
Resolution:
     w/U12: 0.03° at 20°C (0.05° at 68°F); 
     w/ZW: 0.02°C at 25°C (0.04°F at 77°F); 
     w/UX120-006M, MX1104, and MX1105: 0.002° at 25°C (0.003° at 77°F); 
Drift: <0.1°C (<0.2°F) per year
Response time in air: 2 min. typical to 90% in air moving 1 m/sec (2.2 mph)
Response time in stirred water: 30 sec. typical to 90%.
Operating range: Sensor tip and cable immersion in fresh water up to +50°C (122°F) for 1 year
Housing: Copper-plated sensor tip
Dimensions: 5.1 x 33 mm (0.2 x 1.3 inches)
Weight: 34 g (1.1 oz)