Infrared Thermometer for the Food Industry - HI99551

£

Infrared Thermometer for the Food Industry - HI99551

Details

The Infrared Thermometer for the Food Industry - HI99551 is a durable meter that can be used throughout the food industry. The HI99551 offers features such as a quick, one-second response time, HOLD function, and Hanna’s Battery Error Prevention System (BEPS) that will shut the meter off when the battery power is too low for an accurate measurement.

The non-intrusive nature of the HI99551 is particularly attractive in the food industry since it translates itself into substantial savings by leaving products intact, especially those sealed or pre-wrapped. This type of non-intrusive measurement is also useful when the surface temperature is high, for difficult-to-reach places, or hygiene requirements must be followed.

 

Features at-a-glance

°C Readout - Measurements are displayed in degrees Celsius on the clear, easy to read LCD display.

Optic Coefficient - The optic coefficient is the distance between the sensor and the measured object is an important factor in infrared measurement. With a 3:1 relationship between the distance and object area, the HI99551 can measure an area with a diameter that is one-third of the distance between the sensor and the object.

Fixed Emissivity - Emissivity is the ratio of infrared radiation emitted by an object to that emitted by a perfect black body at the same temperature. The HI99551 was designed to measure the temperature of objects with an emissivity of 0.95, which is characteristic of most objects and surfaces being measured.

HOLD Function - The HOLD function freezes the display to allow the user time to record readings when taken in hard to reach places.

Battery Error Prevention System (BEPS) - The Battery Error Prevention System will shut the meter off when the battery power is too low for an accurate measurement.

Low Battery Indicator - When the battery level is below 10%, a warning symbol will blink to indicate low battery condition.

Temperature Range -10 to 300°C (HI99551-00); -20.0 to 199.9°C (HI99551-10)
Temperature Resolution 1°C (HI99551-00); 0.1°C (HI99551-10)
Temperature Accuracy ±2% of reading or ±2°C
IR Sensor Response Time 1 second
IR Sensor Optic Coefficient 3:1 (ratio of distance to target diameter)
IR Minimum Distance 30 mm (1.2’’)
Battery Type/Life 9V / approximately 150 hours of continuous use
Environment 0 to 50°C (32 to 122°F); RH max 95%
Dimensions 143 x 80 x 38 mm (5.6 x 3.2 x 1.5’’)
Weight 320 g (11.3 oz)
Ordering Information HI99551 - [ y ] y = 00 IR range from -10 to 300°C y = 10 IR range from -20 to 199.9°C