Digital Refractometer for % Fructose by Weight Analysis - HI96802
£
    The HI96802 is a rugged, portable digital refractometer for food products is designed to report the content of aqueous solutions containing sugar as % fructose by weight (%w/w). The HI96802 report the results with an accuracy of ±0.2%. The operation of the meter is simplified with only two buttons: one button is to calibrate with distilled or deionized water and the other to take a measurement. All readings are automatically compensated for temperature variations according to the ICUMSA Methods Book standard and displayed with a 1.5 second response time. The sealed flint glass prism and stainless steel well are easy to clean. Just wipe with a soft cloth in preparation for the next sample. Sample size as small as 2 metric drops (100 μl) Sample size as small as 2 metric drops (100 μl) Sealed stainless steel well with high grade optical prism made of flint glass Sealed stainless steel well with high grade optical prism made of flint glass Fast 1.5 second response time for temperature compensated reading Fast 1.5 second response time for temperature compensated readings
Digital Refractometer for % Glucose by Weight Analysis - HI96803
£
    The HI96803 is a rugged, portable digital refractometer for food products designed to report the content of aqueous solutions containing sugar as % glucose by weight (% w/w). The HI96803 report the results with an accuracy of ±0.2%. The operation of the meter is simplified with only two buttons: one button is to calibrate with distilled or deionized water and the other to take a measurement. All readings are automatically compensated for temperature variations according to the ICUMSA Methods Book standard and displayed within a 1.5 second response time. The sealed flint glass prism and stainless steel well are easy to clean. Just wipe with a soft cloth in preparation for the next sample. Sample size as small as 2 metric drops (100 μl) Sample size as small as 2 metric drops (100 μl) Sealed stainless steel well with high grade optical prism made of flint glass Sealed stainless steel well with high-grade optical prism made of flint glass Fast 1.5 second response time for temperature compensated reading Fast 1.5 second response time for temperature compensated readings
Digital Refractometer for % Invert Sugar by Weight Analysis - HI96804
£
    The HI96804 is a rugged, portable digital refractometer for food products designed to report the content of aqueous solutions containing sugar as % invert sugar by weight. The HI96804 report the results with an accuracy of ±0.2%. The operation of the meter is simplified with only two buttons: one button is to calibrate with distilled or deionized water and the other to take a measurement. All readings are automatically compensated for temperature variations according to the ICUMSA Methods Book standard and displayed within a 1.5 second response time. The sealed flint glass prism and stainless steel well are easy to clean. Just wipe with a soft cloth in preparation for the next sample. Sample size as small as 2 metric drops (100 μl) Sample size as small as 2 metric drops (100 μl) Sealed stainless steel well with high grade optical prism made of flint glass Sealed stainless steel well with high-grade optical prism made of flint glass Fast 1.5 second response time for temperature compensated reading Fast 1.5 second response time for temperature compensated readings
Digital Refractometer for Measuring Sodium Chloride in Food - HI96821
£
    The HI96821 is a rugged, portable digital refractometer designed for sodium chloride (NaCl) measurement. The HI96821 displays NaCl concentration four different ways: g/100 g, g/100 mL, specific gravity, and °Baume. The instrument’s high accuracy and simple operation gives reliable results each and every time. All readings are automatically compensated for temperature variations and displayed with a 1.5 second response time. The sealed flint glass prism and stainless steel well are easy to clean. Just wipe with a soft cloth in preparation for the next sample. Sample size as small as 2 metric drops (100 μl) Sample size as small as 2 metric drops (100 μl) Sealed stainless steel well with high grade optical prism made of flint glass Sealed stainless steel well with high-grade optical prism made of flint glass Fast 1.5 second response time for temperature compensated reading Fast 1.5 second response time for temperature compensated readings
Foodcare Cheese pH Tester - HI981032
£
    Designed to bring simplicity to pH testing during the cheese making process, the HI981032 Cheese pH Tester is designed for direct measurement. The built-in probe features open junction, low temperature conical glass tip, and food safe PVDF body making it ideal for measuring the pH of almost all types of cheeses and curds. ±0.05 pH accuracy Comes with all the necessary solutions and batteries- everything you need to get started measuring right away. Specialized electrode for spot checking of pH during the cheese making process.
Foodcare Milk pH Tester - HI981034
£
    Designed to bring simplicity to pH testing during milk processing, the HI981034 Milk pH Tester is engineered to withstand the tough environment of milk processing plants. The built-in probe features an open junction, conical glass tip, and glass body making it ideal for measuring the pH of milk during processing. ±0.05 pH accuracy Comes with all the necessary solutions and batteries- everything you need to get started measuring right away. Specialized electrode for pH spot checking during milk processing.