pH/EC/TDS Multiparameter Probe with CAL Check - HI1285-6

£

pH/EC/TDS Multiparameter Probe with CAL Check - HI1285-6

 

Details

Hanna Instruments offers a wide variety of electrodes that are designed for many different applications. The sensing material, body material, and connection type used are just some of the design considerations.

hi1285-6 electrode

Pre-Amplified pH Electrode

The pH electrode circuit has a built-in amplifier that serves to reduce the effects of electrical noise on the high impedance pH measurement. Electrical noise can come from motors and pumps that are common in greenhouses. The single reference junction design of the pH electrode has a cloth junction that allows ion movement between the inner gel electrolyte and the sample being measured. The advantage of the cloth junction is that it can be extracted from the probe, exposing a fresh surface when readings become drifty or erratic. These features make this probe ideal for use in fertilizer solutions.

 

Amperometric EC/TDS Sensor

EC/TDS readings are performed by a two-pin amperometric sensor. An alternating voltage is applied to the sensor and the amount of current that passes between the two stainless steel pins determines the amount of dissolved ionic solids present.

 

Built-In Temperature Sensor

pH and EC/TDS readings must be temperature compensated in order to obtain accurate results. The built-in temperature sensor of the HI1285-6 provides a speedy temperature reading which is then used to adjust the pH and EC/TDS results accordingly.

 

Polypropylene Body

The polypropylene body of the HI1285-6 houses all three sensors within a sturdy, single body design. This body material is suitable for a wide range of applications and excels in measurements with portable meters due to its durability. The fins around the spherical glass pH bulb minimizes breakage due to accidental bumping or dropping of the electrode. The polypropylene plastic is a high-quality plastic that is chemically resistant to many aggressive chemicals.

 

DIN Connector with CAL Check

The HI1285-6 uses a DIN connector. This type of connector is generally proprietary to the meters they are supplied with and may not be interchangeable. The connection of the HI1285-6 enables the CAL Check function on the HI9813-6 portable multiparameter meter.

Reference Cell Type single, Ag/AgCl
Junction Type/Flow Rate cloth
Type of Electrolyte gel
Body Material polypropylene
Glass Type LT
Tip / Shape spheric (8 mm)
Matching Pin no
Max. Pressure 0.1 bar
Optimum pH Range 0 to 13
Temperature Operating Range 0 to 50°C (32 to 122°F)
Body Length/Overall Length 95 mm / 185 mm
Temperature Sensor yes
Outer Diameter 16 mm
Cable 7-pole; 1 m (3.3')
Connector Type DIN
Amplifier yes
Recommended Use Greenhouses, hydroponics, environmental monitoring, water treatment, boilers, cooling towers
Notes To be used with HI9813-6 series

 