AD-4408C

£

AD-4408C

Specifications
 Analog Unit
Minimum input sensitivity 0.15µV/d
Zero adjustment range -35mV to +35mV (-7mV/V to +7mV/V)
Load cell excitation DC5V±5%, 120mA
Equipped with remote sensing
Up to 8 load cells(350Ω) can be connected.
Temperature coefficient Zero; ±0.02µV/ °C(Typ.)
±0.1µV/ °C(Max.)
Span; ±3ppm/ °C(Typ.)
±15ppm/ °C(Max.)
Non-linearity 0.005% of F.S.
Maximum input noise 0.3µVp-p
Maximum measurement voltage -35mV to +35mV (-7mV/V to +7mV/V)
Minimum input impedance 10MΩ
A/D conversion method Sigma Delta
A/D resolution Approx.16,000,000 counts
Maximum display resolution 999,999d (Less than 20,000d recommended)
A/D conversion rate 100 times/sec.
Calibration Actual load calibration or digital span calibration without actual load
 Digital Unit
Display element Measurement data display: 7-segment 6-digit green LED with 14.6mm high characters
Polarity display: Green LED (1)
Status display: Red LEDs (6)
Measurement data display unit Switch to net weight value (NET) or gross weight value (GROSS).
Display range:0 to 999,999d (Select division from 1, 2, 5, 10, or 50)
Units:Affix a "g","kg",or"t"unit sticker
Status display ZERO, STABLE, GROSS, NET, HOLD,and___(selected function in operation)
 External I/O
CC-Link I/O Up to 64 devices can be connected with one master unit by selecting the number of occupied stations when configured with the AD-4408C.
Standard serial output 20mA current loop signal (exclusive output for A&D peripheral devices)
 General specifications
Power AC100 to 240V (+10%-15%) (50/60Hz)
Power consumption Approx.10VA
Operating temperature and humidity -10°C to 40°C/85%RH or less(no condensation)
Physical dimensions 144(W) × 72(H) × 135(D) mm (including protruding parts)
Panel cutout size 138 × 68 mm
Dust and water-proof The IP65 display is dust and water-proof when mounted into a panel (When the provided rubber packing is affixed)
Weight Approx. 800g
 Standard Accessories
Instruction manual, connector for CC-Link, rubber packing, terminal strip cover, capacity plate and unit stickers


CADCAD File(DXF)  Some characters may be garbled as the original CAD data is in Japanese.

 

Easy-to-use weighing indicator specifically for CC-Link.
Realizes both an extremely fast response speed and stable weighing in high vibration environments.
Enhances the performance of weighing devices that structurally have a source of vibration.
Wide zero adjustment range.

PDFAD-4408C brochure (PDF 878KB)
PDFHPDF brochure (PDF 466KB)
PDFManual (PDF 1,066KB)
MOVIEDemonstration of the high-performance digital filtering function (YouTube)

سجل معنا في القائمة البريدية ليصل اليك كافة المستجدات والعروض التي هي محل اهتمامك