iris Visible Spectrophotometer - HI801

£

iris Visible Spectrophotometer - HI801

 

Details

 

Superior design for superior results.

iris can test a wide variety of analytical measurements and is capable of measuring in a spectral range of 340 nm to 900 nm.

With the compact design of its advanced optical system, iris can be used in almost any sized space while providing accurate and consistent results. The split beam optical system allows iris to automatically compensate for any drift in light source, resulting in superior accuracy.

 

No need for measurement conversions.

Whether you are testing for chlorine or running enzymatic assays, our spectrophotometer will conveniently display results in the units that matter most to you. iris can measure in transmittance, absorbance, and concentration based on your need.

 

The convenience of pre-programmed methods with the option to expand.

iris comes pre-programmed with more than 80 commonly used chemical analysis methods to help you get started. Simply update these methods by connecting to a computer or flash drive.

Customize your iris with up to 100 personal methods. iris will guide you through the method creation process step-by-step. For added versatility, each method can include up to 10 calibration points, five different wavelengths, and up to five reaction timers.

Easily access your favorite methods directly from the home screen to save time.

Built in timers make make measuring seamless. The countdown timer displays the time remaining until a measurement will be taken, ensuring consistent results between measurements and users. If you get stuck, the tutorial mode will walk you through the steps.

 

Change sample size easily.

With our universal cuvette holder and auto-recognition feature, cuvette sizes can be changed when needed. The programmed cuvette size will be displayed on the screen every time you test to ensure that the proper path length is being used by the meter when calculating measurements for correct results.

 

Round Vial Square

 

Worry free replacements.

iris uses a tungsten-halogen lamp for greater energy efficiency, longer service life, and improved light quality for a wide variety of wavelengths. Replacement lamps are shipped pre-aligned and ready for installation so that you can get back to testing.


 

Designed for dynamic environments.

iris' compact profile and long-lasting battery make it easy to set up anywhere in your lab. The rechargeable lithium ion battery lasts for 3,000 measurements, or 8 hours – well over a full day of use out in the field.

 

 

Quality data without the hassle.

Export your results with a USB drive or direct PC link organized by sample ID, method, or date range. Save data as a .pdf or .csv for maximum data integrity or flexibility – all without the use of specialized software.

 

Menu navigation that makes sense.

Quickly navigate between screens with custom keys, and access your favorite methods directly from the home screen with our “favorite methods” feature.

 

Sort and share your data.

Save data as a .pdf or .csv for maximum data integrity or flexibility. Have the freedom to choose the file format that's best for you.

All of your important information is easily visible.

With a 6” display, the screen is large and easy to read. The high contrast makes every character on the display stand out even during outdoor use. The wide viewing angle allows for measurements to be seen from far away, so while working around the lab it is not necessary to hover over the meter to see the measurements.

 

Zero resistance with a capacitive touch pad.

Menu buttons are part of the display. Built to be fully sealed and easy to clean, the meter recognizes key touches even through gloves.

pH Range 6.5 to 8.5 pH
pH Resolution 0.1 pH
pH Accuracy ±0.1 pH
pH Method Adaptation of the Phenol Red method
Oxygen, Dissolved Range 0.0 to 10.0 mg/L (as O2 )
Oxygen, Dissolved Resolution 0.1 mg/L
Oxygen, Dissolved Accuracy ±0.4 mg/L ±3% of reading
Oxygen, Dissolved Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Azide modified Winkler method
Absorbance Range 0.000 to 3.000 Abs
Absorbance Resolution 0.001 Abs
Absorbance Accuracy 5 mAbs at 0.000-0.500 Abs 1% at 0.500-3.000 Abs
Alkalinity Range 0 to 500 mg/L (as CaCO3 )
Alkalinity Resolution 1 mg/L
Alkalinity Accuracy ±5 mg/L ±5% of reading
Alkalinity Method Colorimetric Method
Seawater Alkalinity Range 0 to 300 mg/L (as CaCO3 )
Seawater Alkalinity Resolution 1 mg/L
Seawater Alkalinity Accuracy ±5 mg/L ±5% of reading
Seawater Alkalinity Method Colorimetric Method
Aluminum Range 0.00 to 1.00 mg/L (as Al3+)
Aluminum Resolution 0.01 mg/L
Aluminum Accuracy ±0.04 mg/L ±4% of reading
Aluminum Method Adaptation of the aluminon method.
Ammonia Range Low Range:0.00 to 3.00 mg/L (as NH3 -N)
Medium Range: 0.00 to10.00 mg/L (as NH3 -N)
High Range: 0.0 to 100.0 mg/L (as NH3 -N)
Ammonia Resolution Low and Medium Range: 0.01 mg/L
High Range: 0.1 mg/L
Ammonia Accuracy Low Range: ±0.04 mg/L ±4% of reading
Medium Range: ±0.05 mg/L ±5% of reading
High range: ±0.5 mg/L ±5% of reading
Ammonia Method Adaptation of the ASTM Manual of Water and Environmental Technology, D1426 Nessler method.
Anionic Surfactants Range 0.00 to 3.50 mg/L (as SDBS)
Anionic Surfactants Resolution 0.01 mg/L
Anionic Surfactants Accuracy ±0.04 mg/L ±3% of reading
Anionic Surfactants Method Adaptation of the USEPA method 425.1 and Standard Methods for the Examination of Water and Wastewater, 20th edition, 5540C, Anionic Surfactants as MBAS
Bromine Range 0.00 to 8.00 mg/L (as Br2 )
Bromine Resolution 0.01 mg/L
Bromine Accuracy ±0.08 mg/L ±3% of reading
Bromine Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, DPD method
Calcium Range 0 to 400 mg/L (as Ca2+)
Calcium Resolution 1 mg/L
Calcium Accuracy ±10 mg/L ±5% of reading
Calcium Method Adaptation of the Oxalate method
Carbon Dioxide Range 0.00 to 2.00 mg/L (as ClO2 )
Carbon Dioxide Resolution 0.01 mg/L
Carbon Dioxide Accuracy ±0.10 mg/L ±5% of reading
Carbon Dioxide Method Adaptation of the Chlorophenol Red method
Chemical Oxygen Demand Range Low Range: 0 to 150 mg/L
Medium Range: 0 to 1500 mg/L (Note - ISO reagents only valid to 1000 mg/L)
High Range: 0 to 15000 mg/L
Chemical Oxygen Demand Resolution 1 mg/L
Chemical Oxygen Demand Accuracy Low Range: ±5 mg/L or ±4% of reading
Medium Range: ±15 mg/L or ±4% of reading
High Range: ±150 mg/L or ±2% of reading
Chemical Oxygen Demand Method Adaptation of the USEPA 410.4
Chloride Range 0.0 to 20.0 mg/L (as Cl)
Chloride Resolution 0.1 mg/L
Chloride Accuracy ±0.5 mg/L ±6% of reading
Chloride Method Adaptation of the mercury(II) thiocyanate method
Chlorine Dioxide Range 0.00 to 2.00 mg/L (as ClO2 )
Chlorine Dioxide Resolution 0.01 mg/L
Chlorine Dioxide Accuracy ±0.10 mg/L ±5% of reading
Chlorine Dioxide Method Adaptation of the Chlorophenol Red method
Free Chlorine Range Ultra Low Range : 0.000 to 0.500 mg/L (as Cl2 )
Low Range : 0.00 to 5.00 mg/L (as Cl2)
High Range : 0.00 to 10.00 mg/L (as Cl2)
Free Chlorine Resolution Ultra Low Range : 0.001 mg/
Low Range : 0.01 mg/L
High Range : 0.01 mg/L
Free Chlorine Accuracy Ultra Low Range : ±0.020 mg/L ±3% of reading
Low Range : ±0.03 mg/L ±3% of reading
High Range : ±0.03 mg/L ±3% of reading
Total Chlorine Range Ultra Low Range : 0.000 to 0.500 mg/L (as Cl2 )
Low Range : 0.00 to 5.00 mg/L (as Cl2)
High Range : 0.00 to 10.00 mg/L (as Cl2)
Ultra High Range : 0 to 500 mg/L (as Cl2 )
Total Chlorine Resolution Ultra Low Range : 0.001 mg/L
Low Range : 0.01 mg/L
High Range : 0.01 mg/L
Ultra High Range : 1 mg/L
Total Chlorine Accuracy Ultra Low Range : ±0.020 mg/L ±3% of reading
Low Range : ±0.03 mg/L ±3% of reading
High Range : ±0.03 mg/L ±3% of reading
Ultra High Range : ±3 mg/L ±3% of reading
Chromium, Hexavalent Range Low Range : 0 to 300 µg/L (as Cr(VI))
High Range : 0 to 1000 µg/L (as Cr(VI))
Chromium, Hexavalent Resolution Low Range : 1 µg/L
High Range : 1 µg/L
Chromium, Hexavalent Accuracy Low Range : ±10 µg/L ±4% of reading
High Range : ±5 µg/L ±4% of reading at 25 °C
Chromium, Hexavalent Method Adaptation of the ASTM Manual of Water and Environmental Technology, D1687, Diphenylcarbohydrazide method
Color, Water Range 0 to 500 PCU (Platinum Cobalt Units)
Color, Water Resolution 1 PCU
Color, Water Accuracy ±10 PCU ±5% of reading
Color, Water Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Colorimetric Platinum Cobalt method
Color, Maple Syrup Range 0.00 to 100.00 %T
Color, Maple Syrup Resolution 0.01 %T
Color, Maple Syrup Accuracy ±3% of reading
Color, Maple Syrup Method Direct measure
Copper Range Low Range : 0.000 to 1.500 mg/L (as Cu)
High Range : 0.00 to 5.00 mg/L (as Cu)
Copper Resolution Low Range :0.001 mg/L
High Range : 0.01 mg/L
Copper Accuracy Low Range : ±0.010 mg/L ±5% of reading
High Range : ±0.02 mg/L ±4% of reading
Copper Method Adaptation of the EPA method
Cyanide Range 0.000 to 0.200 mg/L (as CN-)
Cyanide Resolution 0.001 mg/L
Cyanide Accuracy ±0.005 mg/L ±3% of reading
Cyanide Method Pyridine-Pyrazalone
Cyanuric Acid Range 0 to 100 mg/L (as CYA)
Cyanuric Acid Resolution 1 mg/L
Cyanuric Acid Accuracy ±1 mg/L ±15% of reading
Cyanuric Acid Method Adaptation of the turbidimetric method
Fluoride Range Low Range : 0.00 to 2.00 mg/L (as F)
High Range : 0.0 to 20.0 mg/L (as F)
Fluoride Resolution Low Range : 0.01 mg/L
High Range : 0.1 mg/L
Fluoride Accuracy Low Range : ±0.03 mg/L ±3% of reading
High Range : ±0.5 mg/L ±3% of reading
Fluoride Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, SPADNS method
Hardness, Total Range Low Range : 0 to 250 mg/L (as CaCO3 )
Medium Range : 200 to 500 mg/L (as CaCO3 )
High Range : 400 to 750 mg/L (as CaCO3 )
Hardness, Total Resolution 1 mg/L
Hardness, Total Accuracy Low Range : ±5 mg/L ±4% of reading
Medium Range : ±7 mg/L ±3% of reading
High Range : ±10 mg/L ±2% of reading
Hardness, Total Method Adaptation of the EPA recommended method 130.1
Hardness, Calcium Range 0.00 to 2.70 mg/L (as CaCO3 )
Hardness, Calcium Resolution 0.01 mg/L
Hardness, Calcium Accuracy ±0.11 mg/L ±5% of reading
Hardness, Calcium Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Calmagite method
Hardness, Magnesium Range 0.00 to 2.00 mg/L (CaCO3 )
Hardness, Magnesium Resolution 0.01 mg/L
Hardness, Magnesium Accuracy ±0.11 mg/L ±5% of reading
Hardness, Magnesium Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, EDTA Colorimetric method
Hydrazine Range 0 to 400 µg/L (as N2H4 )
Hydrazine Resolution 1 µg/L
Hydrazine Accuracy ±4% of full scale reading
Hydrazine Method Adaptation of the ASTM Manual of Water and Environmental Technology, method D1385, p-Dimethylaminobenzaldehyde method
Iodine Range 0.0 to 12.5 mg/L (as I2 )
Iodine Resolution 0.1 mg/L
Iodine Accuracy ±0.1 mg/L ±5% of reading
Iodine Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, DPD method
Iron Range Low Range : 0.000 to 1.600 mg/L (as Fe)
High Range : 0.00 to 5.00 mg/L (as Fe)
Iron Resolution Low Range : 0.001 mg/L
High Range : 0.01 mg/L
Iron Accuracy Low Range : ±0.010 mg/L ±8% of reading
High Range : ±0.04 mg/L ±2% of reading
Iron Method Low Range : Adaptation of the TPTZ Method
High Range : Adaptation of the EPA Phenanthroline method 315B, for natural and treated waters
Magnesium Range 0 to 150 mg/L (as Mg2+)
Magnesium Resolution 1 mg/L
Magnesium Accuracy ±5 mg/L ±3% of reading
Magnesium Method Adaptation of the Calmagite method
Manganese Range Low Range : 0 to 300 µg/L (as Mn)
High Range : 0.0 to 20.0 mg/L (as Mn)
Manganese Resolution Low Range : 1 µg/L
High Range : 0.1 mg/L
Manganese Accuracy Low Range : ±10 µg/L ±3% of reading
High Range : ±0.2 mg/L ±3% of reading
Manganese Method Low Range : Adaptation of the PAN Method
High Range : Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Periodate method
Molybdenum Range 0.0 to 40.0 mg/L (as Mo6+)
Molybdenum Resolution 0.1 mg/L
Molybdenum Accuracy ±0.3 mg/L ±5% of reading
Molybdenum Method Adaptation of the mercaptoacetic acid method
Nickel Range Low Range : 0.000 to 1.000 mg/L (as Ni)
High Range : 0.00 to 7.00 g/L (as Ni)
Nickel Resolution Low Range : 0.001 mg/L
High Range : 0.01 g/L
Nickel Accuracy Low Range : ±0.010 mg/L ±7% of reading
High Range : ±0.07g/L ±4% of reading
Nickel Method Low Range : Adaptation of the PAN method
High Range : Adaptation of the photometric method
Nitrate Range 0.0 to 30.0 mg/L (as NO3 - N)
Chromotropic Acid : 0.0 to 30.0 mg/L (as N03--N)
Nitrate Resolution 0.1 mg/L
Nitrate Accuracy ±0.5 mg/L ±10% of reading
Chromotropic Acid : ±1.0 mg/L or ±3% of reading
Nitrate Method Adaptation of the cadmium reduction method
Chromotropic Acid : Chromotropic acid method
Nitrite Range Marine Ultra Low Range : 0 to 200 µg/L (as N02 -N)
Low Range : 0 to 600 µg/L (as NO2 -N)
High Range : 0 to 150 mg/L (as NO2-)
Nitrite Resolution Marine Ultra Low Range : 1 µg/L
Low Range : 1 µg/L
High Range : 1 mg/L
Nitrite Accuracy Marine Ultra Low Range : ±10 µg/L ±4% of reading
Low Range : ±20 µg/L ±4% of reading
High Range : ±4 mg/L ±4% of reading
Nitrite Method Marine Ultra Low Range : Adaptation of the EPA Diazotization method 354.1
Low Range : Adaptation of the EPA Diazotization method 354.1
High Range : Adaptation of the Ferrous Sulfate method
Nitrogen, Total Range Low Range : 0.0 to 25.0 mg/L (as N)
High Range : 10 to 150 mg/L (as N)
Nitrogen, Total Resolution Low Range : 0.1 mg/L
High Range : 1 mg/L
Nitrogen, Total Accuracy Low Range : ±1.0 mg/L or ±5% of reading
High Range : ±3 mg/L or ±4% of reading
Nitrogen, Total Method Chromotropic acid method
Oxygen, Scavenger Range Carbohydrazide : 0.00 to 1.50 mg/L (as Carbohydrazide)
Diethylhydroxylamine)(DEHA) : 0 to 1000 µg/L (as DEHA)
Hydroquinone : 0.00 to 2.50 mg/L (as Hydroquinone)
Iso-ascorbic Acid :0.00 to 4.50 mg/L (as Iso-ascorbic acid)
Oxygen, Scavenger Resolution Carbohydrazide : 0.01 mg/L
Diethylhydroxylamine)(DEHA) : 1 µg/L
Hydroquinone : 0.01 mg/L
Iso-ascorbic Acid : 0.01 mg/L
Oxygen, Scavenger Accuracy Carbohydrazide : ±0.02 mg/L ±3% of reading
Diethylhydroxylamine)(DEHA) : ±5 µg/L ±5% of reading
Hydroquinone : ±0.04 mg/L ±3% of reading
Iso-ascorbic Acid : ±0.03 mg/L ±3 % of reading
Oxygen, Scavenger Method Adaptation of the iron reduction method
Ozone Range 0.00 to 2.00 mg/L (as O3 )
Ozone Resolution 0.01 mg/L
Ozone Accuracy ±0.02 mg/L ±3% of reading
Ozone Method Colorimetric DPD Method
Phosphate Range Low Range : 0.00 to 2.50 mg/L (as PO4 3-)
High Range : 0.0 to 30.0 mg/L (as PO4 3-)
Phosphate Resolution Low Range : 0.01 mg/L
High Range : 0.1 mg/L
Phosphate Accuracy Low Range : ±0.04 mg/L ±4% of reading
High Range : ±1.0 mg/L ±4% of reading
Phosphate Method Low Range : Adaptation of the Ascorbic Acid method
High Range : Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Amino Acid method
Phosphorous, Acid Hydrolyzable Range 0.00 to 1.60 mg/L (as P)
Phosphorous, Acid Hydrolyzable Resolution 0.01 mg/L
Phosphorous, Acid Hydrolyzable Accuracy ±0.05 mg/L or ±5% of reading
Phosphorous, Acid Hydrolyzable Method Adaptation of the EPA method 365.2 and Standard Methods for the Examination of Water and Wastewater, 20th edition, 4500-P E, ascorbic acid method.
Phosphorous, Reactive Range Low Range : 0.00 to 1.60 mg/L (as P)
High Range : 0.0 to 32.6 mg/L (as P)
Phosphorous, Reactive Resolution Low Range : 0.01 mg/L
High Range : 0.1 mg/L
Phosphorous, Reactive Accuracy Low Range : ±0.05 mg/L or ±4% of reading
High Range : ±0.5 mg/L or ±4% of reading
Phosphorous, Reactive Method Adaptation of the EPA method 365.2 and Standard Methods for the Examination of Water and Wastewater, 20th edition, 4500-P E, ascorbic acid method.
Phosphorous, Total Range Low Range : 0.00 to 1.15 mg/L (as P)
High Range : 0.0 to 32.6 mg/L (as P)
Phosphorous, Total Accuracy Low Range : 0.01 mg/L
High Range : 0.1 mg/L
Phosphorous, Total Resolution Low Range : ±0.05 mg/L or ±6% of reading
High Range : ±0.5 mg/L or ±5% of reading
Phosphorous, Total Method Low Range : Adaptation of the EPA method 365.2 and Standard Methods for the Examination of Water and Wastewater, 20th edition, 4500-P E, ascorbic acid method.
High Range : Adaptation of the Standard Methods for the Examination of Water and Wastewate
Potassium Range Low Range : 0.0 to 20.0 mg/L (as K)
Medium Range : 10 to 100 mg/L (as K)
High Range : 20 to 200 mg/L (as K)
Potassium Resolution Low Range : 0.1 mg/L
Medium Range : 1 mg/L
High Range : 1 mg/L
Potassium Accuracy Low Range : ±2 mg/L ±7% of reading
Medium Range : ±10 mg/L ±7% of reading
High Range : ±20 mg/L ±7% of reading
Potassium Method Adaptation of the Turbidimetric Tetraphenylborate method
Silica Range Low Range : 0.00 to 2.00 mg/L (as SiO2 )
High Range : 0 to 200 mg/L (as SiO2 )
Silica Resolution Low Range : 0.01 mg/L
High Range : 1 mg/L
Silica Accuracy Low Range : ±0.03 mg/L ±3% of reading
High Range : ±1 mg/L ±5% of reading
Silica Method Low Range : Adaptation of the ASTM Manual of Water and Environmental Technology, D859, Heteropoly Molybdenum Blue method
High Range : Adaptation of the USEPA Method 370.1 for drinking, surface and saline waters, domestic and industrial wastes and
Silver Range 0.000 to 1.000 mg/L (as Ag)
Silver Resolution 0.001 mg/L
Silver Accuracy ±0.020 mg/L ±5% of reading
Silver Method Adaptation of the PAN method
Sulfate Range 0 to 150 mg/L (as SO42-)
Sulfate Resolution 1 mg/L
Sulfate Accuracy ±5 mg/L ±3% of reading
Sulfate Method Sulfate is precipitated with barium chloride crystals
Zinc Range 0.00 to 3.00 mg/L (as Zn)
Zinc Resolution 0.01 mg/L
Zinc Accuracy ±0.03 mg/L ±3% of reading
Zinc Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Zincon method
Wavelength Range 340 to 900 nm
Wavelength Resolution 1 nm
Wavelength Accuracy ±1.5 nm
Measurement Modes Transmittance (% T), absorbance (abs), concentration with choice of units (ppm, mg/L, ppt, ºf, ºe, ppb, meq/L, μg/L, PCU, Pfund, pH, dKH, ºdH, meq/kg or no measurement unit)
Wavelength Selection automatic, based on the selected method (editable for user methods only)
Optical System split beam sample and reference light detectors
Wavelength Calibration internal, automatic at power-on, visual feedback
Spectral bandwidth 5 nm (full width at half maximum)
Stray Light <0.1 % T at 340 nm with NaNO2
Programs (Factory/User) up to 150 factory (85 pre-loaded); up to 100 user developed
Sample Cell 16 mm round, 22 mm round, 13 mm vial, 10 mm square, 50 mm rectangular (with automatic detection)
Data Points Stored up to 9999 measured values
Export Capability .csv file format, .pdf file format
Connectivity 1 micro USB port for charging and PC connectivity
Connectivity (1) USB - A (mass storage host); (1) USB - B (mass storage device)
Power Supply 15 VDC power adapter; 10.8 VDC Li-Ion rechargeable battery
Battery Type/Life 3000 measurements or 8 hours
Environment 0 to 50 °C (32 to 122 °F); 0 to 95% RH
Weight 3 kg (6.6 lbs)
Dimensions 155 x 205 x 322 mm (6.1 x 8.0 x 12.6")
Ordering Information HI801 is supplied with 22 mm sample cuvette and cap (4), 10 mm square, 13 mm round and 16 mm round cuvette adapters, cloth for wiping cuvettes, scissors, USB cable, lithium ion rechargeable battery, 115VAC to 15VDC power adapter, USB drive, instruction manual, and instrument quality certificate.

 