edge® Multiparameter DO Meter - HI2040
edge® Multiparameter DO Meter - HI2040
Details
edge® is packed with many cutting-edge features to ensure accuracy and usability.
Digital Electrodes
edge® electrodes are highly advanced, featuring a built-in microchip that stores calibration information that is automatically retrieved by edge® once the electrode is plugged in. These digital electrodes also feature an easy to plug in 3.5 mm connector so you never have to worry about the right angle or aligning pins.
Clark Type Polarographic DO Probe
edge®HI764080 DO probe has an integrated temperature sensor incorporated into the thin ½” PEI body for automatic temperature compensation of dissolved oxygen measurements. The HI764080 probe uses screw on replaceable caps with a PTFE (Polytetrafluoroethylene) membrane that is easily replaced in the field as well in the lab. The supplied HI7041S is a concentrated Potassium Chloride fill solution used with the Clark-type polarographic technology. With this technology, an external voltage is applied to the platinum cathode and silver anode to establish a current that is proportional to the concentration of oxygen in a solution.
3.5 mm Probe Input
Plugging an electrode in has never been simpler; no alignments, no broken pins, just connect the 3.5 mm plug and get started.
edge® is incredibly versatile. It can be used in a variety of ways and in a variety of environments without taking up the space of a traditional benchtop meter.
Wall Mount
Using the wall mount cradle (included), edge® can be placed on a wall, leaving a zero footprint on the benchtop space. The cradle has a built-in connector to power edge® and charge its batteries. edge®'s zero footprint is designed to save you valuable benchtop space.
Cradle and Electrode Holder
edge® is equipped with a benchtop cradle with an adjustable swivel electrode holder to charge and hold the edge® securely in place at the optimum viewing angle.
edge® is incredibly thin and weighs only 8.8 oz., has an 8-hour battery life, and dual USB inputs.
Two USB Ports
edge® includes one standard USB for exporting data with a flash drive and a second micro-USB port for you to connect to a computer for file export and for charging your edge® when the cradle is not available.
Data Logging
edge® allows you to store up to 1000 log records of data. Data sets include readings, GLP data, date and time.
Basic Mode
You can use edge® in Basic Mode, ideally for routine measurements for a simplified screen and features.
pH Range | -2.000 to 16.000 pH, -2.00 to 16.00 pH, ±1000 mV |
---|---|
pH Resolution | 0.001 pH, 0.01 pH, 0.1 mV |
pH Accuracy | ±0.002 pH, ±0.01 pH, ±0.2 mV |
pH Calibration | Automatic, up to 3 points (5 points*) calibration, 5 standard (7 standard*) buffers available (1.68*, 4.01 or 3.00, 6.86, 7.01, 9.18, 10.01, 12.45*) and 2 custom buffers* |
pH Temperature Compensation | ATC: -5.0 to 100.0ºC; 23.0 to 212.0°F* |
pH CAL Check (electrode diagnostics) | glass and reference junction diagnostics ( HI 11311 & HI 12301 only), out of calibration range , probe condition, response time |
EC Range | 0.00 to 29.99 μS/cm, 3.00 to 29.99 μS/cm, 30.0 to 299.9 μS/cm, 300 to 2999 μS/cm, 3.00 to 29.99 mS/cm, 30.0 to 200.0 mS/cm, up to 500.0 mS/cm, absolute conductivity ‡ |
---|---|
EC Resolution | 0.01 μS/cm, 00.1 μS/cm, 0.01 μS/cm, 0.01 mS/cm, 00.1 mS/cm |
EC Accuracy | ±1% of reading (±0.05 μS/cm or 1 digit, whichever is greater) |
EC Calibration | 1 Cell Factor calibration; 6 standards available: 84, 1413 μS/cm, 5.00, 12.88, 80.0, 111.8 mS/cm, 1 point offset: 0.00 μS/cm |
TDS Range | 0.00 to 14.99 ppm (mg/L), 15.0 to 149.9 ppm (mg/L), 150. to 1499. ppm (mg/L), 1.50 to 14.99 g/L, 15.0 to 100.0 g/L, up to 400.0 g/L absolute TDS ‡ (with 0.80 factor) |
TDS Resolution | 0.01 ppm, 0.1 ppm, 1 ppm, 0.01 g/L, 0.1 g/L |
TDS Accuracy | ±1% of reading (±0.03 ppm or 1 digit, whichever is greater) |
TDS Calibration | through EC calibration |
EC/TDS Temperature Compensation | Automatic -5 to 100 ºC (23 to 212 ºF); NoTC - can be selected to measure absolute conductivity |
Temperature Correction Coefficient | 0.00 to 6.00% / ºC (for EC and TDS only). Default value is 1.90% / ºC |
EC to TDS Conversion Factor | 0.40 to 0.80 (default value is 0.50) |
Salinity (% NaCl) Range | 0.0 to 400.0% NaCl * |
---|---|
Salinity (% NaCl) Resolution | 0.1% NaCl |
Salinity (% NaCl) Accuracy | ±1% of reading (@25ºC/77ºF) |
Salinity (% NaCl) Calibration | 1 point with HI 7037L 100% NaCl sea water standard |
Salinity (PSU) Range | 2.00 to 42.00 PSU * |
Salinity (PSU) Resolution | 0.01 PSU |
Salinity (PSU) Accuracy | ±1% of reading (@25ºC/77ºF) |
Salinity (PSU) Calibration | through EC calibration |
Salinity Range | 0.0 to 80.0 g/L * |
Salinity Resolution (ppt) | 0.01 g/L |
Salinity Accuracy (ppt) | ±1% of reading (@25ºC/77ºF) |
Salinity Calibration (ppt) | through EC calibration |
Oxygen, Dissolved Range | 0.00 to 45.00 ppm (mg/L), 0.0 up to 300.0% saturation |
---|---|
Oxygen, Dissolved Resolution | 0.01 ppm, 0.1% saturation |
Oxygen, Dissolved Accuracy | ±1 digit, ±1.5% of reading |
Oxygen, Dissolved Calibration | one or two points at 0% (HI 7040 solution) and 100% (in air) |
Oxygen, Dissolved Temperature Compensation | ATC: 0 to 50 ºC; 32.0 to 122.0 °F |
Salinity Compensation | 0 to 40 g/L (with 1 g/L resolution) |
Altitude Compensation | -500 to 4000 m (with 100 m resolution) |
Temperature Range | -20.0 to 120.0 ºC, -4.0 to 248.0 °F |
---|---|
Temperature Resolution | 0.1 °C, 0.1 °F |
Temperature Accuracy | ±0.5 °C, ±1.0 °F |
DO Probe | HI 764080 (included) |
---|---|
Logging Type | Manual log-on-demand (Max. 200 logs); Manual log-on-stability (Max. 200 logs); Interval logging *** (Max. 600 samples; 100 lots) |
Logging Memory | up to 1000*** records |
Connectivity | 1 micro USB port for charging and PC connectivity, 1 USB port for storage |
Battery Type/Life | Built-in rechargeable battery with up to 8 hours of continuous use |
Power Supply | 5 VDC adapter (included) |
Environment | 0 to 50°C (32 to 122°F), RH max 95% non-condensing |
Dimensions | 202 x 140 x 12.7mm (8” x 5.5” x 0.5”) |
Weight | 250 g (8.82 oz) |
Ordering Information | HI2040 includes: HI764080 Dissolved Oxygen electrode, HI7041S refill electrolyte solution, (2) DO membrane caps, (2) DO membrane cap o-rings,USB cable, benchtop docking station with electrode holder, wall mount cradle, 5 VDC power adapter, instruction manual, and quality certificate. |
Notes | *Standard Mode Only ** Temperature limits will be reduced to actual probe/sensor limits. ‡Absolute conductivity (or TDS) is the conductivity (or TDS) value without temperature compensation. |
|
سجل معنا في القائمة البريدية ليصل اليك كافة المستجدات والعروض التي هي محل اهتمامك