edge® Multiparameter pH Meter - HI2020

£

edge® Multiparameter pH Meter - HI2020

 

Details

In Cradle

edge® is packed with many cutting edge features to ensure accuracy and usability.

Digital Electrodes

Digital Electrodes

edge electrodes are highly advanced, featuring a built-in microchip that stores calibration information that is automatically retrieved by edge once the electrode is plugged in. These digital electrodes also feature an easy to plug in 3.5 mm connector so you never have to worry about the right angle or aligning pins.

Sensor Check


Sensor Check

When used with Hanna’s pH electrodes equipped with a matching pin, edge constantly checks the impedance of the pH measuring electrode to notify you in real time in the event of glass breakage. During calibration, Sensor Check checks the state of the junction. The reference junction is also evaluated and reported on the display.

3.5mm Probe Input

3.5 mm Probe Input

Plugging an electrode in has never been simpler; no alignments, no broken pins, just connect the 3.5 mm plug and get started.

 

Mounted

edge® is incredibly versatile. It can be used in a variety of ways and in a variety of environments without taking up the space of a traditional benchtop meter.

wall mount

Wall Mount

Using the wall mount cradle (included), edge can be placed on a wall, leaving zero footprint on the benchtop space. The cradle has a built-in connector to power edge and charge its batteries. edge's zero footprint is designed to save you valuable benchtop space.

Cradle

Cradle and Electrode Holder

edge is equipped with a benchtop cradle with an adjustable swivel electrode holder to charge and hold the edge securely in place at the optimum viewing angle.

sides

edge® is incredibly thin and weighs only 8.8 oz., has an 8 hour battery life, and dual USB inputs.

usb

Two USB Ports

edge includes one standard USB for exporting data with a flash drive and a second micro USB port for you to connect to a computer for file export and for charging your edge when the cradle is not available.

data logging

 

Data Logging

edge allows you to store up to 1000 log records of data. Data sets include readings, GLP data, date and time.

basic mode

 

Two Operating Modes

edge can be used in Extended or Basic Operating Modes. Extended Mode enables all features available while the Basic Mode reduces the amount of features to a very simple operation. For example, in extended mode edge offers 5 point calibration with 2 custom buffers while in basic mode calibration can only be performed to 3 points with 5 preprogrammed buffers.

Video


pH Range -2.000 to 16.000 pH, -2.00 to 16.00 pH, ±1000 mV
pH Resolution 0.001 pH, 0.01 pH, 0.1 mV
pH Accuracy ±0.002 pH, ±0.01 pH, ±0.2 mV
pH Calibration 5 points (Standard mode) 1.68, 4.01 (3.00†), 6.86, 7.01, 9.18, 10.01, 12.45, and two custom buffers; 3 points (Basic mode) 4.01; 6.86; 7.01; 9.18; 10.01
pH Temperature Compensation ATC: -5.0 to 100.0ºC; 23.0 to 212.0°F*
pH CAL Check (electrode diagnostics) Probe condition, response time, glass and reference junction diagnostics ( HI 11311 & HI 12301 only)
EC Range 0.00 to 29.99 μS/cm, 30.0 to 299.9 μS/cm, 300 to 2999 μS/cm, 3.00 to 29.99 mS/cm, 30.0 to 200.0 mS/cm, up to 500.0 mS/cm (absolute EC)**
EC Resolution 0.01 μS/cm, 0.1 μS/cm, 1 μS/cm, 0.01 mS/cm, 0.1 mS/cm
EC Accuracy ±1% of reading (±0.05 μS/cm or 1 digit, whichever is greater)
EC Calibration 1 point offset calibration (0.00 μS/cm in air), 1 point slope calibration in EC standard 84 μS/cm, 1413 μS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm and 111.8 mS/cm
TDS Range 0.00 to 14.99 ppm (mg/L), 15.0 to 149.9 ppm (mg/L), 150 to 1499 ppm (mg/L), 1.50 to 14.99 g/L, 15.0 to 100.0 g/L, up to 400.0 g/L (absolute TDS)**, with 0.80 conversion factor
TDS Resolution 0.01 ppm, 0.1 ppm, 1 ppm, 0.01 g/L, 0.1 g/L
TDS Accuracy ±1% of reading (±0.03 ppm or 1 digit, whichever is greater)
TDS Calibration through EC calibration
EC/TDS Temperature Compensation ATC (0.0 to 100.0ºC; 32.0 to 212.0 °F), NoTC
Temperature Correction Coefficient 0.00 to 6.00%/°C (for EC and TDS only), default value is 1.90%/°C
EC to TDS Conversion Factor 0.40 to 0.80
Salinity (% NaCl) Range 0.0 to 400.0% NaCl***
Salinity (% NaCl) Resolution 0.1% NaCl
Salinity (% NaCl) Accuracy ±1% of reading (@25ºC/77ºF)
Salinity (% NaCl) Calibration 1 point with HI 7037L 100% NaCl sea water standard
Salinity (PSU) Range 2.00 to 42.00 PSU***
Salinity (PSU) Resolution 0.01 PSU
Salinity (PSU) Accuracy ±1% of reading (@25ºC/77ºF)
Salinity (PSU) Calibration through EC calibration
Salinity Range 0.0 to 80.0 g/L***
Salinity Resolution (ppt) 0.01 g/L
Salinity Accuracy (ppt) ±1% of reading (@25ºC/77ºF)
Salinity Calibration (ppt) through EC calibration
Oxygen, Dissolved Range 0.00 to 45.00 ppm (mg/L), 0.0 up to 300.0% saturation
Oxygen, Dissolved Resolution 0.01 ppm, 0.1% saturation
Oxygen, Dissolved Accuracy ±1 digit, ±1.5% of reading
Oxygen, Dissolved Calibration one or two points at 0% (HI 7040 solution) and 100% (in air)
Oxygen, Dissolved Temperature Compensation ATC: 0 to 50 ºC; 32.0 to 122.0 °F
Salinity Compensation 0 to 40 g/L (with 1 g/L resolution)
Altitude Compensation -500 to 4000 m (with 100 m resolution)
Temperature Range -20.0 to 120.0 ºC, -4.0 to 248.0 °F
Temperature Resolution 0.1 °C, 0.1 °F
Temperature Accuracy ±0.5 °C, ±0.9 °F
pH Electrode HI11310 pH electrode (included)
Logging Type Manual log-on-demand (Max. 200 logs); Manual log-on-stability (Max. 200 logs); Interval logging *** (Max. 600 samples; 100 lots)
Logging Memory up to 1000*** records
Connectivity 1 micro USB port for charging and PC connectivity, 1 USB port for storage
Battery Type/Life Built-in rechargeable battery with up to 8 hours of continuous use
Power Supply 230VAC to 5 VDC adapter (included)
Environment 0 to 50°C (32 to 122°F), RH max 95% non-condensing
Dimensions 202 x 140 x 12.7mm (8” x 5.5” x 0.5”)
Weight 250 g (8.82 oz)
Ordering Information HI2020 pH kit includes: HI11310 glass body, refillable pH electrode with temperature sensor, pH 4 buffer solution sachets, pH 7 buffer solution sachets, pH 10 buffer solution sachets, electrode cleaning solution sachets,USB cable, benchtop docking station with electrode holder, wall mount cradle, 5 VDC power adapter, instruction manual, and quality certificate.
Notes * temperature limits will be reduced to actual probe/sensor limits
** with temperature compensation function disabled
*** for standard mode only
† pH 3.00 is only visible when using specific pH electrodes and will replace 4.01pH buffer

 