Wall Mounted EC Digital Controller HI23211-2
£
Wall Mounted EC Digital Controller HI23211-2
Details
Fail Safe Alarm System
- Hanna’s exclusive Fail Safe Alarm System protects against problems caused by power supply failure or signal interruption, which are typical risks in industrial environments. An alarm condition is indicated by a red LED, located directly on the front panel of the controller.
Simple Installation
- HI22111 has mounting holes molded into the housing to assure simple, quick and secure installation without the need for additional hardware.
Isolated Recorder Output
- To enhance troubleshooting and the ability to record data while monitoring, simply attach a recording device to the instrument’s 4 to 20 mA output contacts, conveniently located on the front panel, to obtain a copy of the results on demand.
Good Laboratory Practices (GLP)
- The GLP feature allows users to store and recall data about system status for ultimate traceability.
Quality Construction
- Housed in a rugged, modular, fiber-reinforced polypropylene housing that will resist the harmful effects of most chemicals.
Password Protection
- The Hanna password protection feature keeps these controllers safe from tampering. Only users with the proper password can change the settings of these controllers.
Weight | 1.6 |
---|
EC Range | 0.0 to 199.9 µS/cm; 0 to 1999 µS/cm; 0.00 to 19.99 mS/cm; 0.0 to 199.9 mS/cm |
---|---|
EC Resolution | 0.1 µS/cm, 1 µS/cm; 0.01 mS/cm, 0.1 mS/cm |
EC Accuracy | 0.5% f.s. |
EC Calibration | automatic, 1 point |
EC/TDS Temperature Compensation | automatic or manual from -10 to 100°C with Pt100 probe; β adjustable from 0.00 to 10.00%/°C |
Temperature Range | 10.0 to 100.0°C |
---|---|
Temperature Resolution | 0.1 °C |
Temperature Accuracy | ±0.5 °C (0 to 70°C); ±1 °C (outside) |
Alarm Relay Set Point | electromechanical relay SPDT contact output, 5A - 250 VAC, 5A - 30 VDC (resistive load) fuse protected: 5A, 250V, 250V fast fuse |
---|---|
Consent Relay | electromechanical relay SPDT contact outputs, 5A-250 VAC, 5A - 30 VDC (resistive load) (HI211YZ and HI212YZ), fuse protected: 5A, 250V fast fuse |
Analog Ouput Signal | 0-10 VDC, 0-5 VDC or 1-5 VDC; 0-1mA, 0-20 mA or 4-20mA |
Digital Output Signal | RS485 |
Baud Rate | RS 485 baud rate 1200, 2400, 4800 and 9600 |
Power Consumption | 15 VA |
Over Current Protection | 400 mA, 250V, fast fuse |
Enclosure | Fiber-reinforced, self-extinguishing ABS |
Installation Category | II |
EC/TDS Probe | four-ring conductivity probe with built-in 3-wire Pt100 temperature sensor or conductivity probe + external Pt100 (not included) |
---|---|
Display | LCD |
Power Supply | 230 ±10% VAC |
Environment | 0-50 °C; RH max 85% non-condensing |
IP Rating | IP54 |
Dimensions | 221 x 181 x 86 mm (8.7 x 7.1 x 3.4’’) |
Weight | 1.6 kg (3.5 lb.) |
Ordering Information | Supplied with instructions. |
|