Panel-mounted Conductivity Controller - HI700 Series

£

Panel-mounted Conductivity Controller - HI700 Series

 

Details

HI 700 series controllers are real time microprocessor-based EC controllers. They provide accurate measurements, flexible ON/OFF or proportional control capabilities, analog input and output, RS485 port, dual setpointand alarm signal.The system is composed of a case inside which the signal conversion circuitry, the microprocessor circuitry and the outputpower drivers are contained.

With self-diagnostic features and extractable terminals, installation and maintenance are fast and simple. Password protection guarantees that the calibration and predetermined parameters cannot be altered unnecessarily. The controllers can operate with four-ring probe or 4-20 mA signal. They accept probes with or without a built-in Pt100 temperature sensor. 

HI700 Series Conductivity Controller's FEATURES/BENEFITS:

Display 

  • Large LCD with 4 ½ 17 mm digits and 3 ½ 10 mm digits.

Indicator LEDs

  • Four LEDs are provided for signaling the energizing of relay 1 and 2 (yellow LEDs) and alarm relays (a greenand a red LED).

PC Connectivity (HI700222 only)

  • RS485 standard is a digital transmission method that allows long lines connections. Its current-loop system makes this standard suitable for data transmission in noisy environments. Data transmission from the instrument to the PC is possible with the HI 92500 Windows® compatible application software offered by Hanna Instruments.

Friendly Interface

  • A menu-driven display aids the user throughout the operations with running messages and clear prompts. All relevant parameters can be simply adjusted and will remain memorized until overwritten.

Programmable Hold System

  • The hold function allows the user to stop the regulating action of the controller for programmable time periods. It is possible to activate the hold periods in correspondence to programmed operations, such as plant maintenance and cleaning procedures.

Programmable Cleaning Cycles

  • Heavy-duty applications often require almost continuous probe maintenance. Elements such as suspended solids, fat, oils, pigments and microorganisms can quickly deposit and soil the electrode. Programmable cleaning cycles allow for scheduled maintenance to keep the probe functioning optimally.

Automatic Temperature Compensation

  • A 2-wire Pt100 can be connected to ensure fast, accurately compensated readings even during sudden temperature fluctuations.

Good Laboratory Practice (GLP) 

  • Last calibration data internally recorded for traceability including calibration date and time, cell constant, calibration solution values.

Relays

  • 1 or 2 output relays for low conductivity or highconductivity dosage (COM, NO and NC contacts) and 1output relay for alarm condition (COM, NO and NC con-tacts)

Calibration

  •  Automatic 1 point calibration. alibration and Setup procedures allowed only through an unlock password.

Mult Range Conductivity Measurment

  • Four different EC working ranges (0 to 199.9μS; 0 to1999μS; 0 to 19.99mS; 0 to 199.9mS)

 

 
EC Range 0.0 to 199.9 µS/cm; 0 to 1999 µS/cm; 0.00 to 19.99 mS/cm; 0.0 to 199.9 mS/cm
EC Resolution 0.1 µS; 1 µS; 0.01 mS; 0.1 mS
EC Accuracy ±0.5% f.s. (EC)
EC Calibration automatic or manual at 1 point
EC/TDS Temperature Compensation automatic or manual, -10 to 100°C with adjustable temperature coefficient from 0.00 to 10.00%/°C
Temperature Range -10.0 to 100.0°C
Temperature Resolution 0.1 °C
Temperature Accuracy ±0.5°C (0 to 70°C); ±1°C (outside)
Alarm Relay Set Point contact output SPDT 5A-250 VAC, 5A-30 VDC (resistive load), fuse protected (2A, 250V fast fuse)
Dosing Control two contact outputs SPDT 5A-250 VAC, 5A-30 VDC (resistive load), fuse protected (2A, 250V fast fuse)
Analog Input Signal 4-20 mA
Analog Ouput Signal analog: isolated 0-1 mA, 0-20 mA and 4-20 mA; 0-5 VDC, 1-5 VDC and 0-10 VDC or digital: RS485 bi-directional opto-isolated
Power Consumption 15 VA
Over Current Protection 5A, 250V fast fuse
Panel Cutout 140 x 140 mm
Power Supply 115 VAC ±10%; 50/60 Hz
Environment 0 to 50°C (32 to 122°F); RH max 95% non-condensing
Dimensions 144 x 144 x 170 mm
Weight 1.6 kg (3.5 lb.)
Ordering Information Each HI700 model is supplied with mounting brackets and instructions.

 

سجل معنا في القائمة البريدية ليصل اليك كافة المستجدات والعروض التي هي محل اهتمامك